GINCON CHAPTER 03
    CHAPTER 03 / LOAD SENSING · 第三章 / 负载敏感

    THE BEAUTY OF SYSTEMS系统之美

    Load-Sensing Directional Control Valve / 负载敏感多路阀

    Explore the three-position, four-way main spool, two-way pressure compensator and LS feedback. Compare how pre- and post-compensated systems distribute flow as multiple actuators compete for limited pump supply.
    观察三位四通主阀芯、二通压力补偿器及 LS 反馈。比较多执行器同时动作时,阀前补偿和阀后补偿如何分配有限的泵流量。
    P, T, A and B are the main ports. LS carries load-pressure feedback. / P、T、A、B 是主油口,LS 通道传递负载压力信号。
    01 / WORK SECTION · 工作片

    PV32 pre-compensated work section / PV32 阀前补偿工作片

    Supply / 进油Return / 回油LS pressure signal / LS 压力信号Energized coil / 通电线圈
    A/B closed / A、B 工作口关闭

    Work flow / 工作流量0.00 L/min
    Effective area / 有效开口面积0%
    Metering Δp / 计量压差—
    Pump pressure / 泵压 P—

    Drag the PVM lever or use the spool slider. Visible contours are traced from the registered section photo. Actuator outlines come from STEP. / 拖动 PVM 操纵杆或阀芯滑块。可见轮廓按实物照片配准描绘,端盖轮廓取自 STEP。

    02 / INTERACTIVE LAB · 交互实验

    One pump, two cylinders / 一台泵,两支油缸

    Section 1 / 第 1 联
    Pump定量泵 3-way inlet三通进油片 Cylinder 1油缸 1 Cylinder 2油缸 2 Highest LS feedback / 最高负载压力反馈 Tank / 油箱 T P · 泵压 LS · 最高负载信号
    Pump pressure / 泵压 P
    Highest LS reference / 最高 LS 参考
    Inlet bypass / 进油片旁通
    Section / 工作联Area / 面积Demand / 需求Delivered / 实得Meter in → out / 计量前→后Δp / 计量压差
    1
    2

    03 / CRANE LAB · 随车吊复合动作

    Four-section crane operation / 随车吊四联复合动作

    System setting 260 bar. Slew section 160 bar. Loads and demand flows below are adjustable teaching inputs. / 系统设定 260 bar,回转联设定 160 bar。下列负载和流量需求为可调教学输入。

    Pump pressure / 泵压
    Highest LS / 最高 LS
    Inlet bypass / 进油片旁通
    Pressure relief / 溢流
    CRANE MOTION / 随车吊动作示意

    Each section shows delivered flow / requested flow. / 各联读数依次为实得流量和需求流量。

    04 / COMPENSATION · 补偿原理

    Two jobs, two compensators / 两类补偿器,各管什么

    3-way compensator / 三通补偿器

    In a fixed-pump open-center LS circuit, the inlet compensator regulates supply and diverts excess flow to T. At neutral the LS signal unloads, and the pump flow returns through the inlet bypass. During regulation, P follows the highest LS plus the system margin.

    定量泵开中心 LS 系统中,进油片的三通补偿器调节供油压力,把多余流量旁通回 T。中位时 LS 卸压,泵流量经进油片旁通。调节范围内,P 约等于最高 LS 加系统控制压差。

    2-way compensator / 二通补偿器

    The work section controls the pressure drop across its metering edge. Within regulation, the same opening produces nearly the same flow as load changes.

    工作片的二通补偿器调节主阀芯计量口压差。补偿有效时,同一阀芯开度下,负载变化对流量影响较小。

    Q = Cd A(x) √(2Δpmeter/ρ)

    Pre-compensated work section / 阀前补偿工作片

    P → local compensator → spool metering edge → A/B. The meter outlet is at local load pressure in the idealized circuit.

    P → 单联补偿器 → 主阀芯计量口 → A/B。理想回路中,计量口下游为本联负载压力。常规阀前补偿缺流时,低负载联可能先获得流量,高负载联可能减速或停住。

    Post-compensated work section / 阀后补偿工作片

    P → spool metering edge → local compensator → A/B. In the flow-sharing example, the compensators use the highest LS reference to keep a common metering drop. Under shortage, both commanded flows are scaled by the same factor.

    P → 主阀芯计量口 → 单联补偿器 → A/B。流量共享架构以最高 LS 为参考,使各联计量压差共同下降,需求流量按相同比例缩减。

    Work-section cutaway reserved / 阀后工作片剖面预留,待新工作片资料接入。

    Inlet for pre-compensated sections / 阀前补偿系统的进油片

    A fixed pump can use a three-way inlet bypass, with highest LS fed to the inlet regulator. In a variable-pump circuit, a closed-center inlet passes the LS signal to the pump controller.

    定量泵方案可用三通旁通式进油片,最高 LS 反馈到进油片调压阀。采用变量 LS 泵时,闭中心进油片把 LS 信号传给泵控制器。

    Inlet for post-compensated sections / 阀后补偿系统的进油片

    The supply controller establishes the system margin. The valve group also routes highest LS to the work-section compensators in the illustrated sharing architecture. Inlet and signal passages depend on the pump and valve family.

    供油控制器建立系统压差,流量共享结构还把最高 LS 送到各工作片补偿器。定量泵旁通与变量泵闭中心方案的油道及反馈连接须按所选阀组核对。

    Inlet cutaways reserved / 两类进油片剖面预留。

    Flow sharing under saturation and energy loss / 流量分配、抗流量饱和与能量损失

    With enough supply, both layouts regulate the pressure drop across the main spool metering edge. Under shortage, conventional pre-compensation can lose regulation, so the lower-load section may draw more flow and the higher-load section may slow or stall.

    供油充足时,两种结构都能调节主阀芯计量口压差。供油不足时,传统阀前补偿可能失去调节能力,低负载联容易优先得油,高负载联可能减速或停住。

    Sharing example / 共享算例 · Pump / 泵供油 150 L/min · Demand / 两联需求 80 + 120 = 200 L/min · Sharing factor / 共享系数 150 ÷ 200 = 0.75 · Actual flow / 理想阀后共享 60 + 90 = 150 L/min. Bucher example / 布赫算例

    Throttling loss / 节流损失 · Ploss [kW] = Δp [bar] × Q [L/min] ÷ 600. Both layouts lose power across their metering and compensation edges. At the same supply pressure, load pressures and flows, moving the compensator changes where the loss occurs. Some LUDV circuits add directional metering losses. Bypassing 60 L/min from a fixed pump across 100 bar dissipates 10 kW. A variable-displacement pump can reduce this bypass flow.

    两种结构的计量口和补偿器都会耗能。供压、负载压力和流量相同时,补偿器前后移位会改变损失发生的位置。部分 LUDV 回路还存在额外的换向节流压降。定量泵若有 60 L/min 的多余流量跨 100 bar 旁通,损失为 10 kW。变量泵可减小排量,减少这部分旁通流量。

    Variable-speed research / 变转速研究 · A 2025 study combined a variable-speed fixed-displacement pump with adjustable pressure margin and pre-compensation. Its test system used 6.3–13.7% less energy than the study’s LUDV baseline. / 该研究结合变转速定量泵、可调压差与阀前补偿,在特定试验工况下比其 LUDV 对照系统节能 6.3%~13.7%。 Journal of Mechanical Engineering / 机械工程学报

    Compare both layouts in the two-cylinder lab / 在双缸实验中比较两种结构
    Pressure example and diagnostic checks / 压力示例与排查

    At 100 L/min, with loads of 100 and 60 bar and a 14 bar example margin, conventional pre-compensation gives a 114 bar pump target. The two metering inlets are about 114 and 74 bar. The high-load compensator is at the ideal regulation limit.

    泵流量 100 L/min、两联负载 100/60 bar,示例压差 14 bar。常规阀前补偿的泵压目标约 114 bar,两联计量口上游约为 114/74 bar。高负载联处于理想调节边界。压差设定为教学值。

    For abnormal neutral pressure or slow operation across all sections, start with P, LS, and inlet bypass. For one slow section, compare its A/B pressures and check its metering edge and compensator. For uneven compound motion, measure pump flow and compare it with total demand before tracing highest LS.

    中位压力异常或各联都慢,先测 P、LS 和旁通。单联慢,结合 A/B 口压力检查计量口与补偿器。复合动作失调,先比对实测泵流量与总需求,再查最高 LS 信号与各联压差。

    References and model boundary / 资料与模型边界

    PV32 positions follow the supplied photos. The STEP is a surface model. The supplied Sauer-Danfoss L1010481 is a PVG 32 agricultural-module reference. / PV32 阀位以实物照片为准,STEP 为曲面模型。所附 L1010481 是萨澳-丹佛斯 PVG 32 农机模块参考资料。

    The lab uses fixed load pressures and ideal metering. It omits relief, leakage, return backpressure and spool dynamics. / 实验采用给定负载和理想计量,暂略溢流、泄漏、回油背压和阀芯动态。